Operations and Maintenance Manual
_
MPR 4.1
Reader Maintenance Instructions
Confidential UM UM360479-100 Revision: Draft B4 Page 96 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX
05/25/2022 11:18
Kapsch TrafficCom
Configuring synchronization
Prerequisites: Connect a service laptop to the Reader Lane Controller port to access the Web
interface.
See the following procedures for more information.
• Connecting a service laptop to the Reader on page 34
• Changing the service laptop IP address on page 34
• Testing the connection to the reader on page 35
• Accessing the Web interface on page 35
• Synchronization rules on page 62
Note: Reader synchronization is also enabled remotely by the LC if the Remote LC
Configuration is enabled.
Example: TDM only 2 Lane ORT with Shoulders (4-Channel scan) and synchronization
• Frame Sequence panel: Seq #1 set to TDM, Seq#2 set to Sync_1.
• Sync panel: Sync enabled and Sync_1 set. Verify the Sync parameters.
Note: The following procedure indicates how to compose the given example.
2. Go to Tag Protocol web page.
3. Set frame sequence : Seq #1 set to TDM; Seq #2 set to Sync 1.
Result: The following screen is shown as an example.
Note: The Frame Sequence time, circled above in red, should be the same on all readers connected to
the sync circuit to ensure reader sync is achieved.
4. Click the Sync icon on the Frame Sequence panel and set the Sync parameters.
Result: The following screen is shown as an example.