Installing the Reader hardware
Prerequisites: A suitable mounting location has been selected and the earth ground system has been
installed as per IEEE 142-2007, see the earth ground system on page 83.
Note: When handling the Readers and hardware, always follow accepted Electrostatic
Discharge (ESD) practices and standards.
1. Mount the reader as needed, see Figure 5-4: Wall/Shelf Mounting an MPR 4.1 or Figure 5-5: Pole Mounting
an MPR 4.1
2. Connect the Reader ground lug to earth ground:
3. Connect the power cable from the External DC power source to the Reader. Appropriate lightning/surge
protection equipment should be installed between the DC power source input and the earth ground system
at the Reader, see Figure 5-2 on page 85.
Figure 5-2: External DC Supply
Connect the appropriate cables from the Reader to the LC as shown in Figure 5-3: LC Data Cable
installation on page 86.