Operations and Maintenance Manual

_
MPR 4.1
Reader Maintenance Instructions
Confidential UM UM360479-100 Revision: Draft B4 Page 79 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX
05/25/2022 11:18
Kapsch TrafficCom
Table 4-3: List of Fields in a Transaction Log Report
Field
Description
IREAD
Optional initial read report when transponder first enters capture zone. Informational report
VOTE
Transaction report at voting time
POST
Optional post-capture zone report if lane assignment or programming status has changed. Informational
report
Ch
Port number. Indicates the assigned Port (1-8). Port 1 corresponds to the leftmost RF module in the RF rack.
St
Transaction status.
Pgm indicates successful transponder programming.
PU indicates transponder programming status is Unknown (tag left zone before verify could complete).
PF indicates transponder was not programmed successfully.
Read indicates the Reader is in read only mode.
CrossR indicates an informational report (not a transaction).
Txn
Transaction number. Note that transaction numbers may appear to skip when using 2 or more Readers with
Ethernet connection between them.