If the reader detects that the sync bus is driven high prior to the expiry of this delay, the reader exits
delay mode and performs one of the following actions.
Sets its driver high and falls into synchronization frame start delay if programmed
Sets its driver high and begins firing its Frame sequence.
Synchronization frame start delay
Synchronization frame start delay programs how long the Reader waits after Reader-to-Reader sync
has occurred. Its internal driver is set to a high state before firing the next frame and/or frame
sequence.
Sync recovery time
Sync recovery time is a programmable variable that indicates how long the reader searches/waits for
synchronization on the reader network before firing its frame sequence. It is recommended that this
value be programmed at least 125% of the total frame sequence.
If the reader detects that the sync bus is driven high prior to the expiry of this time, the reader exits
recovery mode, sets its driver high and begins firing its frame sequence.
Sync recovery attempt limit:
Sync recovery attempt limit is used to indicate how many Sync Recovery Time periods must expire
before the Reader no longer searches/waits for synchronization before firing its tag acquisition
sequence independent of the reader network. A loss of reader synchronization message will be
transmitted via the lane controller interface.
If this limit is programmed with a zero (0) value, the Reader will always wait for Sync Recovery Time
to expire before firing its sequence.
Sync-on-skipped-sync frame
Sync-on-skipped-sync frame is used when more than 3 protocols are selected in the frame sequence.
A two sequences-skip is used to indicate where the sequence starts.
How Reader synchronization operates at the toll location
After interrogating all of the assigned ports, each Reader will provide a ‘sync ready’ signal on its SYNC
Connector. Only when the configuration parameter Enable Reader to-Reader Sync checkbox is
selected under the SYNC tab does synchronization occur.
As busy Readers become ready they will not send any more RF trigger signals until the sync bus
indicates that all Readers are ready. Once the last Reader in the network generates its ready signal, all
Readers on the sync bus simultaneously generate OBU trigger pulses starting with the RF module in