Note 2: For the FDM protocols it is also necessary to set up Port frequencies for each Port, see
Frequency Selection, page 52
Note 3 : To support read/write operation it is necessary to configure the programming
configuration, see Programming tags, page 55
The following tabs will be used to create the frame sequence
Tag Protocol panel: Seq #1 set to TDM, Seq#2 set to 6B, Seq#3 set to SYNC_1 and Seq#4 set
to 6C, all others set to empty.
TDM panel: Channels 1 to 4 enabled sequentially in slots 1-4.
6B panel: Enable Channels 1 to 4 and select the appropriate Tag Read mode from the pull
down menu. Enable Dual Tag Preamble.
6C panel: Enable Channels 1 to 4 and select the appropriate Tag Read mode and over-air tag
masking from the pull down menus.
Sync panel: Set the Reader-Reader sync parameters.
The detailed steps are as follows
1. Go to the Tag Protocol page Frame Sequence panel.
2. Set Seq #1 to TDM, Seq#2 to 6B, Seq#3 to SYNC_1 and Seq#4 to 6C.
Result: The following screen is shown as an example.
3. Click the TDM icon on the Frame Sequence panel to show TDM protocol settings.
Under the TDM Channel Firing Sequence panel, enable time slot 1 to 4 sequentially for the 4 channels.
Result The following screen is shown as an example.