Operations and Maintenance Manual
_
MPR 4.1
Reader
Operating Instructions
Confidential UM UM360479-100 Revision: Draft B4 Page 60 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
2. Click the dropdown under icon.
Result: The following screen is shown as an example.
3. Select the required protocol
4. Repeat this sequentially for each Seq# (frame) in order to build up a sequence.
Note 1: To build a frame sequence, work from left to right starting in the first frame. To change or
delete frames from a sequence, you must always start with the last frame and work
towards the left.
Note 2: The maximum number of actively transmitting frames (Seq#’s) must be kept to 8 of less.
Sync frames and Dummy frames that do not transmit are not counted.
5. Select the options required under each individual frame type tab for Seq# types selected.
The following three diagrams show examples of different Flexible Over the Air frame sequences that
can be selected using the modular approach.
Figure 3-1: Example: Flexible Over the Air frame sequence (Balanced Protocol Weighting)
TDM Time Slots
Channel
Sequence A
6C TID Read
Request
Sync Block
6B Triple Page
Request
TDM Time Slots
Channel
Sequence A
6B Triple Page
Request
Sync Block
6C TID Read
Request
Channel Sequence A
IAG Read Only
TDM Slot 1: CH1