Operations and Maintenance Manual

_
MPR 4.1
Reader
Operating Instructions
Confidential UM UM360479-100 Revision: Draft B4 Page 30 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
3. OPERATING PROCEDURES
CAUTION:
Improper modification of configuration parameters may adversely
affect system operation. The default values may not be appropriate
for the specific application. It is the system integrator’s responsibility
to tailor the configuration parameters to the specific operating
environment, with the aid of the Kapsch Operations Group.
Starting up the Reader
This procedure outlines the correct way to power on and boot up a Reader.
Prerequisites: External DC Power Source (19 to 30VDC).
1. Connect the external Power source to the MPR 4.1
Result: The POWER LED illuminates green.
2. Wait for the MPR 4.1 to complete its power up cycle (approximately 60 Seconds).
Result: The POWER LED illuminates green. The STATUS LED illuminates green to indicate MPR 4.1 is
functional.
Note: If the STATUS LED indicates an abnormal state, (see Table 6-1: LED Indicator states
explained on page 113) perform the necessary troubleshooting procedure. See Troubleshooting
Methodology on page 111 for more information.
Shutting down the Reader
This procedure outlines the correct way to power down a Reader.
Prerequisites: None.
1. Click Dashboard link located on the upper left side panel.
2. On the Manage panel, click the Shutdown icon.