Operations and Maintenance Manual

_
MPR 4.1
Reader
Operating Instructions
Confidential UM UM360479-100 Revision: Draft B4 Page 24 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
No LED illuminated Indicates that the reader software is not operating.
SYNC Green LED illuminated Indicates that the reader is correctly syncing with
other reader on the sync connection.
Flashing Amber LED illuminated Indicates that the reader is out of sync and
in recovery mode with other readers on the sync connection.
Flashing Red LED illuminated Indicates that the reader is out of sync with
other readers on the sync connection.
No LED illuminated Indicates that Sync is not enabled on the MPR 4.1
reader.
ANT (1 through 4) Green LED illuminated Indicates that the port is actively transmitting.
Flashing Green LED illuminated Indicates that the port is active but a fault
exists on the Port.
No LED illuminated Indicates that the port is not selected.
MPR 4.1 External Connectors
Figure 2-3: MPR 4.1 External Connectors
The MPR 4.1 reader includes the following external interfaces:
Connector Description
ANT 1 A female N type connector for RF connection to one antenna.