Operations and Maintenance Manual
_
MPR 4.1
Reader
Operating Instructions
Confidential UM UM360479-100 Revision: Draft B4 Page 24 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
No LED illuminated – Indicates that the reader software is not operating.
SYNC Green LED illuminated – Indicates that the reader is correctly syncing with
other reader on the sync connection.
Flashing Amber LED illuminated – Indicates that the reader is out of sync and
in recovery mode with other readers on the sync connection.
Flashing Red LED illuminated – Indicates that the reader is out of sync with
other readers on the sync connection.
No LED illuminated – Indicates that Sync is not enabled on the MPR 4.1
reader.
ANT (1 through 4) Green LED illuminated – Indicates that the port is actively transmitting.
Flashing Green LED illuminated – Indicates that the port is active but a fault
exists on the Port.
No LED illuminated – Indicates that the port is not selected.
MPR 4.1 External Connectors
Figure 2-3: MPR 4.1 External Connectors
The MPR 4.1 reader includes the following external interfaces:
Connector Description
ANT 1 A female N type connector for RF connection to one antenna.