Operations and Maintenance Manual

_
MPR 4.1
Reader
Operating Instructions
Confidential UM UM360479-100 Revision: Draft B4 Page 23 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
MPR 4.1 LED Indicators
Figure 2-2: MPR 4.1 Reader LED Indicators
The MPR 4.1 Reader provides the following status information based on the LEDS shown in Figure 2-2: MPR 4.1
Reader LED Indicators.
LED DESCRIPTION
POWER Green LED illuminated Indicates that the MPR 4.1 reader has external
power and all internal power supplies are working correctly.
Flashing Amber LED illuminated Indicates that the MPR 4.1 reader has
external Power but there is a fault with one of the internal power supplies.
No LED illuminated Indicates that the MPR 4.1 reader either has no or
improper external power or a fault with the internal power supplies.
MESSAGE Flashing Amber LED illuminated Indicates that there are recorded errors or
messages that need to be addressed by the user. Example: NTP time offset
exceeded, Lane Controller connection down, Frame Configuration error.
No LED illuminated - Indicates that are no recorded errors or messages.
STATUS Flashing Green LED - Indicates that the reader CPU is functioning correctly.
Flashing Amber LED Indicates that the reader CPU is experiencing heavy
load.
Flashing Red LED - Indicates that the reader CPU is operating under extreme
load.