Operations and Maintenance Manual

_
MPR 4.1
Reader: Appendix
Confidential UM UM360479-100 Revision: Draft B4 Page 240 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
Command
How to execute
Who can
execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
NTP time offset
warning
threshold (ms)
With NTP enabled,
Input threshold in
milliseconds.
user with
Change
Configuration
permissions
NTPMAX
20
1-100
Specify a maximum threshold
(default 20 ms) for the largest
NTP time offset tolerated in
the system. When NTP is
enabled, the reader
periodically checks its NTP
time offset, and if it is greater
than the threshold, change
the NTP status parameter to
one of the Alarm values. An
alert is also shown in the UI
banner.
NTP Server 1, 2,
3 and 4
With NTP enabled,
enter three
different valid NTP
server IP address in
the NTP Server
fields.
user with
Change
Configuration
permissions
NTP__1
NTP__2
NTP__3
NTP__4
N/A
N/A
Sets the NTP server IP
addresses.
Provides the Reader with
four NTP servers it can access
to accurately maintain time
with other Readers in an IR
network.