Operations and Maintenance Manual
_
MPR 4.1
Reader: Appendix
Confidential UM UM360479-100 Revision: Draft B4 Page 238 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
Command
How to execute
Who can
execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
begins sending TCP
Keepalive probes.
TCP (Long-Lived)
Keepalive Probes
Input number in
field.
user with
Change
Configuration
permissions
LcTKaP
3
1-10
For TCP Long-Lived
Connections, specifies the
maximum number of TCP
Keepalive probes the
Reader should send before
dropping the connection.
TCP (Long-Lived)
Keepalive Interval
(sec)
Input time in
seconds.
user with
Change
Configuration
permissions
LcTKaI
2
1-100
For TCP Long-Lived
Connections, specifies the
time (in seconds) between
individual TCP Keepalive
probes.
TCP (Long-Lived)
User Timeout
(msec)
Input timeout in
milliseconds.
user with
Change
Configuration
permissions
LcTUTo
5000
5000-60000
For TCP Long-Lived
Connections, specifies the
maximum time (in
milliseconds) that
transmitted data may
remain unacknowledged by
the Lane Controller (at the