Kapsch TrafficCom
Command
How to execute
Who can
execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
Suppress ATA
'Phantom'
Handshake Reports
Set toggle switch to
ON to suppress
report.
user with
Change
Configuration
permissions
NOATAP
0
0 - 1
Enable to suppress the
reporting of ATA 'Phantom'
Read Handshake Reports. A
read is deemed a 'Phantom'
if the ATA Frame-Check fails
and/or the reader is unable
to extract a valid serial
number from the data.
Lane Controller Page: LC Report Latency by Tag Type Panel
0 - Interior FPT
Delay [ms]
Enter a time (in
milliseconds) in the
0- Interior FPT
Delay field
user with
Change
Configuration
permissions
LYCTL0
0
0-5000
Sets report delay time in
milliseconds for Interior FPT
OBUs (Type 0)
Used to slow down the
transaction report of Type 0
OBUs to the LC for those
legacy sites where the LC is
expecting BADGER Reader
timing