Operations and Maintenance Manual
_
MPR 4.1
Reader: Appendix
Confidential UM UM360479-100 Revision: Draft B4 Page 231 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
Command
How to execute
Who can
execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
Set appropriately, this
feature can help reduce the
incidence of ATA 'Phantom'
reads/reports.
Verify ATA Data
CRC:
From the LC tab on
the Configure
panel
user with
Change
Configuration
permissions
ATAVDC
1
0 - 1
If enabled, instructs the
Reader to perform a CRC
validation check on the
received ATA data. If the
incoming data does not
pass the CRC check,
handshake messages,
Note: if enabled, may be
flagged as invalid, or
suppressed entirely.
Suppress ATA Bad
CRC Handshake
Reports
Set toggle switch to
ON to suppress
report.
user with
Change
Configuration
permissions
NOATAC
0
0 - 1
Enable this option to
suppress the reporting of
ATA Handshake Reports
that have failed an ATA
Data-CRC check.