Operations and Maintenance Manual

_
MPR 4.1
Reader: Appendix
Confidential UM UM360479-100 Revision: Draft B4 Page 221 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
Command
How to execute
Who can
execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
Min Gap Size
(ms)
Input time in ms in
field.
user with
Change
Configuration
permissions
ERDGAP
50
1 - 10000
An early read Specifies the
minimum allowed gap size
Voting Delay
Gap Scaling
Factor (%)
Input percent in
field.
user with
Change
Configuration
permissions
ERDVSF
100
0 - 500
Specifies the voting delay
scaling factor to apply
Minimum Post
Gap HS Ratio (0-
100%)
Input percent in
field.
user with
Change
Configuration
permissions
ERDHSR
50
0 - 100
Specifies the minimum post
gap to cumulative HS ratio
(e.g. 50% means at least half
of the HS on any channel
must be after the RF gap).
Lane Assignment Page: TDM Low Read Logic Panel
Enable Low
Read Logic
Toggle Enable
switch to enable
/disable
user with
Change
Configuration
permissions
LWREAD
0
0 - 1
Delays voting if a long RF gap
right before voting is
detected.