Kapsch TrafficCom
Command
How to execute
Who can
execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
based on the length of the
Sync Cable.
Enable Sync-on-
Skipped-Sync
Sequencing
Set toggle switch to
ON to enable.
user with
Change
Configuration
permissions
SYNSKP
0
0-1
Instruct the reader to search
for the missing sync
sequence to indicate when
the protocol synchronization
is to occur.
Note: This feature should be
used when more than 3
protocols are selected in the
frame sequence.