Operations and Maintenance Manual
_
MPR 4.1
Reader: Appendix
Confidential UM UM360479-100 Revision: Draft B4 Page 212 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
Command
How to execute
Who can
execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
is not seen during the Sync
Search phase.
Note: It is recommended that
this value be set to at least
125% of the total multi-
protocol tag acquisition
sequence.
Sync Frame
Start Delay (µs)
With Custom Sync
Timing enabled,
enter sync frame
start delay in us.
user with
Change
Configuration
permissions
SYNFSD
0
0 us – 255 µs
This value specifies how long
the Reader will delay from
the rising edge of the sync
pulse to the rising edge of the
trigger pulse in the frame.
Sync Delay (ns)
Enter sync delay in
ns.
user with
Change
Configuration
permissions
SYNCDL
0
0 - 10000ns
This value specifies, in 100
nanosecond (ns) increments,
how long the Reader will wait
after Reader-to-Reader
synchronization has occurred
before firing the next tag
acquisition sequence. This
value should be calculated