Command
How to execute
Who can
execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
the reader sync network. If
set to zero, the Reader will
always wait for the Sync
Recovery Time to expire
before firing its tag
acquisition sequence.
Enable Custom
Sync Timing
Set toggle switch to
ON to enable.
user with
Change
Configuration
permissions
SYNCSE
0
0-1
Enables/disable custom sync
timing.
Sync Search
Time (µs)
With Custom Sync
Timing enabled,
enter sync search
time in us.
user with
Change
Configuration
permissions
SYNSTO
100 µs
20 - 65535 µs
Specify how long the Sync
function will search for the
synchronization signal in
microseconds (µs) before
switching to recovery mode.
Sync Recovery
Time (ms)
With Custom Sync
Timing enabled,
enter sync recovery
time in ms.
user with
Change
Configuration
permissions
SYNRTO
20 ms
0 - 65535 ms
Specify how long the Sync
function will attempt
synchronization recovery in
the event that the sync signal