Operations and Maintenance Manual
_
MPR 4.1
Reader: Appendix
Confidential UM UM360479-100 Revision: Draft B4 Page 210 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
Sync
(select Sync in Frame Sequence panel)
Note: Sync cannot be the 1
st
in frame sequence
Command
How to execute
Who can
execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
Reader-to-
Reader Sync.
Enable
When Sync is
selected in frame
sequence, Reader-
to-Reader sync will
be enabled
automatically.
If Sync is
deselected, Reader-
to-Reader sync will
be disabled
automatically.
user with
Change
Configuration
permissions
RFSYNC
0
0 - 1
Controls whether RF
transmission is synchronized
between adjacent readers.
Note: A sync cable to connect
readers is required if Reader-
to-Reader sync is to be
enabled.
Sync. Recovery
Attempt Limit
Enter attempt limit
in field.
user with
Change
Configuration
permissions
SYNRTL
0
0 – 100
This value specifies how
many Sync Recovery Time
Periods must expire before
the reader will no longer
search/wait for sync before
firing its tag acquisition
sequences independently of