Operations and Maintenance Manual

_
MPR 4.1
Reader: Appendix
Confidential UM UM360479-100 Revision: Draft B4 Page 206 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
Command
How to execute
Who can execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
ATA Hold-Off
Delay (µs)
Select hold off
delay in us from
drop-down list.
user with Change
Configuration
permissions
ATAHOD
600 us (3)
0 us (0)
-
1400 µs (7)
(in 200 µs steps)
Specifies how long the ATA
CW transmission is delayed
from the start of the ATA
frame in order to provide a
sufficient gap in air time
from the previous timeslot.
Title 21 Protocol
(select T21 protocol in Frame Sequence panel)
Command
How to execute
Who can
execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
Tag Protocol Page: Title 21 Advanced Panel
Agency ID
Enter a numeric
agency id.
user with
Change
Configuration
permissions
T21AID
0
0- 65535
Specify the desired Title21
Agency ID, in decimal.