Operations and Maintenance Manual
_
MPR 4.1
Reader: Appendix
Confidential UM UM360479-100 Revision: Draft B4 Page 203 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
Command
How to execute
Who can execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
Agency 2 Sub-
Mask (dec)
With 6C Sub-Mask
enabled, enter 6C
Agency ID Sub-
Mask.
user with Change
Configuration
permissions
6CSMA2
0
0-4294967295
Specify the 6C Agency ID Sub-
Mask to use.
Agency 3 Sub-
Mask (dec)
With 6C Sub-Mask
enabled, enter 6C
Agency ID Sub-
Mask.
user with Change
Configuration
permissions
6CSMA3
0
0-4294967295
Specify the 6C Agency ID Sub-
Mask to use.
Tag Protocol Page: 6C Programming Panel
6C Read-Only
Mode
Set Enable toggle
switch to ON to
enable
programming and
OFF for 6C Read-
Only Mode.
user with Change
Configuration
permissions
6CROLY
1
0-1
Configure whether or not the
reader will attempt to perform
6C writes..
6C Try-To-
Program
Timeout [sec]
With 6C
programming
enabled,
user with Change
Configuration
permissions
6C_TTP
500
0-4294967295
Specifies, in seconds, the
duration after which additional
programming attempts will be
made with an existing 6C tag.