Kapsch TrafficCom
Command
How to execute
Who can execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
Multi-tag reads
(Q = 2)
Set toggle switch to
ON to enable.
user with Change
Configuration
permissions
6C__MT
0
0 - 1
Enable to allow multiple ISO
18000-6C tags to be read per
frame, at the expense of a
longer frame time.
When disabled, only one 6C
tag may be read per frame.
When enabled, the 6C Q-value
= 2; when disabled the Q-value
is 0.
6C Mask Select
Select 6C mask
from the drop-
down list.
user with Change
Configuration
permissions
6C_MSK
Standard (0)
Standard (0)
Puerto Rico (1)
Custom (2)
Specify what 6C Read Masking
to use when reading 6C tags.
6C Custom
Mask Select
Select 6C custom
mask from the
drop-down list.
user with Change
Configuration
permissions
6CCMSK
None (0)
None (0)
TOC V2.1 (or later)
(1)
TOC V2.0 (WSDOT)
(2)
Legacy WSDOT (3)
Specify what custom tag
matching option to use when