Kapsch TrafficCom
Command
How to execute
Who can execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
6B GROUP_SELECT
Mask (base 10)
With 6B
GROUP_SELECT
enabled, input
mask.
user with Change
Configuration
permissions
6BMASK
0
0-FF
Specify the 6B
GROUP_SELECT mask
to use (in base 10, not
hex).
6B GROUP_SELECT
Data (Hex)
With 6B
GROUP_SELECT
enabled, input
data.
user with Change
Configuration
permissions
6BDATA
0000000000000000
0000000000000000
-
FFFFFFFFFFFFFFFF
Specify the 6B
GROUP_SELECT Data
to use. Please enter a
16-digit (64-bit)
hexadecimal value.
Initial CW Time (µs)
Select cw time
from the drop-
down list.
user with Change
Configuration
permissions
6BICWT
400 (4)
Off (0)
100 (1) - 1500 (15)
(in 100 µs steps)
Specifies the initial
CW time (in µs)
Dual Tag Preamble
Set toggle switch to
ON to enable
user with Change
Configuration
permissions
6B_DTP
0
0 - 1
Specifies whether or
not the Dual Tag
Preamble is
transmitted during the
ISO 18000-6B frame.