Operations and Maintenance Manual
_
MPR 4.1
Reader: Appendix
Confidential UM UM360479-100 Revision: Draft B4 Page 196 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
ISO 18000-6B Protocol
(select 6B protocol in Frame Sequence panel)
Command
How to execute
Who can execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
Tag Protocol Page: 6B Advanced Panel
6B Read Mode:
Select read mode
from the drop-
down list.
user with Change
Configuration
permissions
6B_RDM
Standard (UDI only) (0)
Standard (UDI only)
(0)
eATA read – Single-
page mode
(UDI+eATA) (1)
eATA read –
3-page mode
(UDI+eATA) (2)
Specifies what mode
to use when reading
ISO 18000-6B tags.
Standard Mode: reads
the UID of the tag
only.
Single-Page eATA
Read Mode: reads
both the UID and the
eATA data in the tag,
one page at a time,
per superframe, and is
a legacy mode that
should be used when