Operations and Maintenance Manual

_
MPR 4.1
Reader: Appendix
Confidential UM UM360479-100 Revision: Draft B4 Page 189 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
Command
How to execute
Who can execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
TC RW Format
(enable)
Set toggle switch to
ON to enable write.
user with Change
Configuration
permissions
rw__RW
0
0-1
Determines whether or not to
program the TC-DATA RW
format field of the tag's R/W
area.
TC Lane Number
(enable)
Set toggle switch to
ON to enable write.
user with Change
Configuration
permissions
rwLANE
1
0-1
Determines whether or not to
program the TC-DATA lane field
of the tag's R/W area.
HOT (High
Occupancy Toll)
lane enable
With HOT Lane
enabled, select the
HOT Lane Enable
check box for each
channel starting
from left to right.
user with Change
Configuration
permissions
HOT_LN
0
0 - 1
Determines whether or not to
program the HOT/HOV lane
field of the tag's R/W area.
Tag Protocol Page: OBU Feedback Panel
(this panel is editable when the reader is NOT in TDM Read-Only Mode and TCP is enabled)
OBU Feedback
(enable)
Set toggle switch to
ON to enable write.
user with Change
Configuration
permissions
rw_OBU
0
0-1
Determines whether or not to
program the TC-DATA OBU
feedback fields of the tag's R/W
area.