Operations and Maintenance Manual
_
MPR 4.1
Reader: Appendix
Confidential UM UM360479-100 Revision: Draft B4 Page 188 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
Command
How to execute
Who can execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
Transaction
number
programming
format
Select the
appropriate
calculation method
from the drop-
down list.
user with Change
Configuration
permissions
TFRM__
Reprogram with
16 bit
sequential
transaction
number. (2)
Do not
reprogram
transaction field.
(0)
Reprogram with
16 bit random
number. (1)
Reprogram with
16 bit sequential
transaction
number. (2)
Reprogram with
8 bit random
number and 8 bit
sequential
number. (3)
Set the way the Reader creates
an OBU transaction number.
TC Date/Time
(enable)
Set toggle switch to
ON to enable write.
user with Change
Configuration
permissions
rwTCDT
0
0-1
Determines whether or not to
program the TC-DATA
date/time field of the tag's R/W
area.