Operations and Maintenance Manual

_
MPR 4.1
Reader: Appendix
Confidential UM UM360479-100 Revision: Draft B4 Page 186 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
Command
How to execute
Who can execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
Enabled: Reader updates traffic
management fields.
Reader ID
Set toggle switch to
ON to enable write
on Reader ID field
in tag.
user with Change
Configuration
permissions
rw_RID
1
0-1
Determines whether or not to
program the TM-DATA reader
ID field of the tag's R/W area.
TM Date/Time
Set toggle switch to
ON to enable write
on TM Date/Time
field in tag.
user with Change
Configuration
permissions
rwTMDT
1
0-1
Determines whether or not to
program the TM-DATA
date/time fields of the tag's
R/W area.
Tag Protocol Page: Toll Collection Programming (TCP) Panel
(this panel is editable when the reader is NOT in TDM Read-Only Mode and TCP is enabled)
Enable TCP
Set Enable toggle
switch to ON to
enable TCP.
user with Change
Configuration
permissions
TCP___
1
0-1
Control if toll collection fields
will be written to OBUs.