Operations and Maintenance Manual
_
MPR 4.1
Reader: Appendix
Confidential UM UM360479-100 Revision: Draft B4 Page 185 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
Command
How to execute
Who can execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
Lane Number
(channel
assignment)
Enter a numeric
value in each
channel number
field.
user with Change
Configuration
permissions
RFLNUM
Per-instance
defaults.
Instance:0
value:1
instance:1
value:2
.
.
.
instance:30
value:31
0-31
Indicate in OBU data which lane
an OBU was in when a
transaction occurred.
Assigns a lane number to each
channel. ATTENTION: this field
should be used with care as the
value may not reflect the
channel on which the tag was
reported.
Tag Protocol Page: Traffic Management Programming (TMP) Panel
(this panel is editable when the reader is NOT in TDM Read-Only Mode)
Enable TMP
Set Enable toggle
switch to ON to
enable TMP.
user with Change
Configuration
permissions
TMP___
1
0-1
Control if traffic management
fields will be written to OBUs.
Disabled: Reader does not
update traffic management
fields.