Operations and Maintenance Manual

_
MPR 4.1
Reader: Appendix
Confidential UM UM360479-100 Revision: Draft B4 Page 177 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
Tag Protocol Page
Command
How to execute
Who can execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
Frame Sequence
Click the Add icon
and select a tag
protocol from the
drop-down list.
user with Change
Configuration
permissions
FRSEQ1
Empty (0)
Empty (0)
Dummy_1 (1)
Dummy_2 (2)
Dummy_3 (3)
Dummy_4 (4)
Sync_1 (5)
Sync_2 (6)
Sync_3 (7)
Sync_4 (8)
TDM (9)
SeGo (12)
6B (13)
6C (14)
ATA (15)
Title21 (17)
Specifies the Frame Sequence
Slot protocol/function.
Used to specify the protocol
firing and/or the
Synchronization Sequence of
the Reader.
Sync is NOT allowed to be the
1
st
in frame sequence.
Only after Dummy_1 is selected
will Dummy_2 appear in drop-
down list for selection and so
on.
Same to Sync. Only after Sync_1
is selected will Sync_2 appear in
drop-down list for selection and
so on.