Operations and Maintenance Manual
_
MPR 4.1
Reader: Appendix
Confidential UM UM360479-100 Revision: Draft B4 Page 175 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
Command
How to execute
Who can
execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
calculating the average
voting time.
Dynamic Voting
Threshold [%]
With Dynamic
Voting Control for a
channel set to
Reader, enter the
voting threshold
percentage in field.
user with
Change
Configuration
permissions
DVTHSD
20
5-100
Sets the voting threshold
percentage
To configure when the
average Voting time is
adjusted. The Voting time will
only be updated when the
Reader determines the
percent change is larger than
the threshold entered here.
Dynamic Voting
Capture Zone
Span Multiplier
With Dynamic
Voting Control for a
channel set to
Reader, enter a
voting time
multiplier in field.
user with
Change
Configuration
permissions
DVCZTM
2
1-5
Sets the Capture Zone Span
Time multiplier
Determines when the Reader
checks for voting time
updates.
Channels Page: Group Panel