Operations and Maintenance Manual
_
MPR 4.1
Reader: Appendix
Confidential UM UM360479-100 Revision: Draft B4 Page 172 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
Command
How to execute
Who can
execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
LPT/FME Voting
time (ms)
Type the voting
time in ms for each
channel.
user with
Change
Configuration
permissions
LPTVTO
300
0-9999
Specifies the time after the
initial entry of the
transponder into the capture
zone at which a VOTE report
is generated. This is a trade-
off between lane
assignments versus latency. A
value of 0 means no voting,
subject to the Programming
Timeout parameter. Specific
to [L]icense [P]late [T]ags and
(F)ront (M)ount (E)€xterior
tags only.
Channel Weight
(%)
In Advanced mode:
Type the channel
weight as a percent
for each channel.
user with
Change
Configuration
permissions
RFWGHT
100
0-100
Enter a value from 0 to 100.
At lane assignment time, the
reader applies the weighting
factor to all channels seeing
the same transponder in a
group. A channel weight of
50 means only half of the