Kapsch TrafficCom
Channels Page
(set Advanced toggle switch to ON to show more settings)
Command
How to execute
Who can
execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
RF State
Select state of RF
module from the
drop down menu
for each channel.
user with
Change
Configuration
permissions
RF_STS
Offline
Offline
Active
Guard
Offline means the MRFM-S
module is off.
Active means the MRFM-S
module is on and reports
transactions on this channel.
Guard means MRFM-S
module is on, but
transactions assigned to this
channel are not reported.
Voting Time
(ms)
Type the voting
time in ms for each
channel.
user with
Change
Configuration
permissions
VOTETO
100
0-9999
Specifies the time after the
initial entry of the
transponder into the capture
zone at which a VOTE report
is generated. A value of 0
means no voting, subject to
the Programming Timeout
parameter.