Operations and Maintenance Manual

_
MPR 4.1
Reader: Appendix
Confidential UM UM360479-100 Revision: Draft B4 Page 166 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
Command
How to execute
Who can
execute
Parameter
Name
Default Value
Parameter
Range
Purpose of command
Site Type
Select sign type in
drop-down list.
user with
Change
Configuration
permissions
SITETY
Plaza
Plaza
ORT (with straddle
antennas)
ORT (no straddle
antennas)
ORT staggered
Lab / table-top demo
This provides an indication of
the site configuration which
is intended to help site
maintainers. This is also used
in the setup wizard to
provide certain parameter
defaults.
General Page: Network Panel
Reader IP
Address
Type an ETHERNET
1 port IP address in
Reader IP Address
field.
user with
Change
Configuration
permissions
LETHIF
192.168.1.50
N/A
Sets the IP address of the
Lane Controller Ethernet
interface
Used to specify an
appropriate ETHERNET 1 IP
address when configuring an
LC network