Synchronization Cable and Terminal Block specifications
An example of the wiring detail is shown in Figure 5-10: Synchronization circuit schematic for three
Readers, page 95. This cable must be run in conduit and should not be run with other cables capable
of inducing RFI or EMI.
Maximum Sync Cable Length
2000 feet (607 meters) max length, sum of all Readers cable segments to hub
1500 feet (457 meters) max length, any one Reader cable segment to hub
Sync Cable Requirements
Temperature: as required for operating environment
Environmental: as required for operating environment (must be waterproof if immersion is possible)
Capacitance: 30 pF/ft or less
Sync Wire: 3 twisted pairs (2 active, 1 spare), shielded, single or multiple drain
Wire gauge: 24 AWG (minimum)
Sync Terminal Block
Temperature and Environmental: as required for operating environment
Number of terminals: [4 X (number of Readers in the sync group) plus 4] e.g. 3 Readers require
(4x3)+4 = 16
Connection: See the example diagram of a three-Reader sync hub connection inFigure 5-10, page 95.