The maximum cable length is limited by the permitted cable signal loss. The maximum cable signal
loss is based on the protocols selected and is limited to the lowest value in the table below of all
protocols enabled.
Protocol
Maximum
cable loss
(dB)
TDM
11
ISO18000-6C
11
ISO18000-6B
7
SeGo
7
Allegro
7
Title 21
?
10374/ATA/AAR S-918
7
Connectors: Use cable assembly tools recommended by the cable manufacturer.
Cable splicing: No splices are allowed, must be a continuous run
Minimum Bend Radius: See Manufacturers recommendation
Finished connection must be weatherproofed using self-amalgamating tape
Cable that run underground or may be submersed in water must be installed in conduit with no other
cables capable of inducing RFI or EMI.