Resetting the Reader configuration to the factory default
Certain field service tests use the factory default configuration. This procedure outlines how to
restore the factory default values without changing the Reader IP addresses.
Prerequisites: Connect a service laptop connected to Lane Controller Port to access the web
interface. Refer to Connecting a service laptop to the Reader, page 34.
Save the current Reader configuration, see Saving the Reader configuration, page 127.
CAUTION:
The factory default configuration should not be restored on a
running Reader. The factory software/firmware may not be
appropriate for the specific application. Save the current
Reader configuration before resetting the Reader configuration
to the factory default.
1. Go to the Save/Load Configuration Web page.
2. Click the Reset reader configuration to defaults icon .
Result: All configuration values, except for the Reader IP addresses, will change to the factory
defaults.
Administration
User administration permissions are needed when a new user account needs to be created, when an
account needs to be changed, or deleted. The user can be given access to any combination of the five
following access areas.
Admin - User
Manage Software
Manage logs
Change Configuration
Creating a new user
This procedure outlines how to create a new user account, and set the user permissions.
Prerequisites: Connect a service laptop connected to the Lane Controller Port to access the web
interface. Refer to Connecting a service laptop to the Reader, page 34. You must have User Admin
permissions.