Operations and Maintenance Manual
_
MPR 4.1
Reader Maintenance Instructions
Confidential UM UM360479-100 Revision: Draft B4 Page 126 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
Result: The software file will be uploaded from the computer to the Reader. When the upload is
complete, the new the software will appear in the table of available software versions as INACTIVE.
Note: To begin using the new software, activate the software (see Activating new software).
Activating new software
The currently active software version becomes inactive once another software version is activated.
The following procedures outline the steps for activating an inactive software version stored on the
Reader.
Prerequisites: You must have Manage Sofware permissions. The Reader must be running normally.
The required software is uploaded to the Reader (see New software/firmware , page 125).
CAUTION:
Activating inactive factory software/firmware on a running
system is not recommended. The factory software/firmware
may not be appropriate for the specific application.
CAUTION:
During software/firmware activation (typically less than 60
seconds), a Reader is unable to process or report transactions.
Software Update:
1. Save the current configuration file, (see Saving the Reader configuration, page 127).
2. On the Reader Software web page. Select the inactive software version to be activated in the available
software version table.
3. Click the Activate icon to activate the software
4. Click Yes to confirm and to acknowledge that the reader will be stopped while switching to a different
software version.
5. If necessary, restore the configuration file saved in step 1 (see Uploading a saved configuration, page 128).
Deleting software
The Factory software and active software cannot be deleted. This procedure outlines the steps for
deleting an inactive software version stored on the Reader.