Operations and Maintenance Manual
_
MPR 4.1
Reader Maintenance Instructions
Confidential UM UM360479-100 Revision: Draft B4 Page 122 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
7. MAINTENANCE PROCEDURES
CAUTION:
Improper modification of configuration parameters may adversely
affect system operation. The default values may not be appropriate
for the specific application. It is the system integrator’s responsibility
to tailor the configuration parameters to the specific operating
environment.
Corrective maintenance procedures
Note: When removing or installing ESD sensitive equipment always follow the accepted practices for
ESD protection.
The inspect, clean, and system re-test methodology is used for all system maintenance. This type of
maintenance consists of the following general steps.
1. Inspect all Reader connections.
Determine if the connections require cleaning. To clean component connector contacts, use a contact
cleaner spray that does not contain a trichloroethylene based solvent or a Freon® based propellant.
Attention: Pre-authorized lane closure is required if the connectors need to be cleaned.
Preventive maintenance procedures and scheduling
Attention: Only Kapsch Service-trained service maintenance personnel are to
perform these tasks.
Once a year:
1. Perform RF measurements to verify the cables and reader. It is recommended a commercial off-the shelf
instrument is used which supports Cable Analyzer Testing, to show faults inside cables, and Voltage
Network Analysis, to verify connection integrity and end to end connectivity and gain.
2. Verify reader output power and power at antenna using a commercial off-the shelf spectrum analyzer.
With power off:
1. Inspect and clean the Reader as needed, depending on the site environmental conditions, such as
contamination by dust. As a minimum, inspect and clean the reader once per year.
2. Inspect the antenna waterproofing and ensure that any seal is secure.
3. Inspect the antenna weep hole. Remove any dust, dirt or other obstructions.