Operations and Maintenance Manual

_
MPR 4.1
Reader Maintenance Instructions
Confidential UM UM360479-100 Revision: Draft B4 Page 121 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX 05/25/2022 11:18
Kapsch TrafficCom
Testing the Synchronization hub cabling
1. If the SYNC LED does not illuminate solid green with another functional reader connected to the
Synchronization circuit, the problem is with the wiring between the reader and the synchronization hub
terminal block.
Testing the MPR 4.1 Antenna Ports
The following test is to verify that all antenna ports of the Reader are functional.
Prerequisites: Connect a service laptop to Lane Controller port to access the web interface. Refer to
Connecting a service laptop to the Reader, page 34.
Note: All four Ports in a Frame Sequence configuration must be enabled to fire, otherwise this
test will not work.
1. Go the Channels we page.
Result: The following screen appears.
2. Set Cht# to Active.
3. Ensure that the selected Antenna LED on the Reader illuminates solid green.
4. From the Channels web page, select Offline from the RF State drop-down list.
5. Ensure that the Antenna LED on the Reader is off.
6. Repeat steps 1 and 5 for each Port.