Reader recovery actions
For certain failures, the Reader will automatically initiate the recovery actions outlined in Table 6-2.
Table 6-2: Failures and the Reader Recovery Actions they trigger
Failure
Reader Recovery Action
CTM Health failure
reinitializes CTM
Ethernet LC link down
re-attempts connection once every second or up
to 10 seconds based on load
Inter-Reader Ethernet link down
switches to Badger style CRA and re-attempts
connection
Testing the LC Ethernet port
This test verifies that a LC Ethernet port is working properly.
Prerequisites: A service laptop.
1. Connect a service laptop directly to LC Ethernet port (see Connecting a service laptop to the Reader, page
34).
Note: Ensure that you can access the web interface with the service laptop (see Accessing the
Web interface, page 35). This confirms the Ethernet port is functional.
Testing the Synchronization Circuit
This first part of this test checks the functionality of the Reader’s Sync Port.
Testing the Sync circuit
1. Disconnect the Synchronization circuit wiring from the Sync port
2. Using two short jumper wires connect Tx+ to Rx+ and Tx- to Rx- on the Sync port, leaving the GND
terminals unconnected (see Sync Port connections, page 140).
3. If the SYNC LED illuminates solid green, the Sync circuit is functioning properly.
4. Reconnect the synchronization circuit to the Sync port.