Kapsch TrafficCom
Constant busy state on sync bus
A Reader that erroneously holds the sync bus in a BUSY state causes all other Readers connected to
the bus to time-out while waiting for the READY state. As a result, all of their SYNC LEDs will be
flashing red. Disconnect each Reader one at a time from the sync hub until the fault clears then
reconnect each Reader in the order of removal until the fault reappears. Service each faulty Reader.
Sync Failure Indicator for incomplete cable connections
The SYNC LED will flash steadily red if there is no activity on the Rx port of the sync connector. If both
transmit and receive connections are cut off from the sync hub the indicator will flash red. If only the
transmit connection is disconnected and there are other Readers in the synchronization network, the
SYNC LED stays green.
Identifying failures on the reader
Reader failure is indicated by any of the following conditions:
• Ethernet LC link down, as indicated on the Reader browser Status page.
• Ethernet IR network link down, as indicated on the Reader browser Status page.
• STATUS LED is red