3. Enter a sample size in the Dynamic Voting Sample Size field.
Note 1: This is the number of previous transactions the Reader includes when calculating the
average capture zone span time.
Note 2: The Reader calculates the capture zone span time after each OBU transaction. The
Reader will not update the Dynamic Voting Time unless the capture zone span time
changes more than the Dynamic Voting Threshold percentage.
4. Enter a percentage in the Dynamic Voting Threshold field.
Configuring Port Weight for straddle antennas
The handshake count of straddle Ports (Ports 1 and 3 in Figure 5-16) typically have less weight
assigned to them than non-straddle Ports (Ports 2, and 4 in Figure 5-16).