Operations and Maintenance Manual
_
MPR 4.1
Reader Maintenance Instructions
Confidential UM UM360479-100 Revision: Draft B4 Page 108 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX
05/25/2022 11:18
Kapsch TrafficCom
5. Enter a time, in seconds (s), in the Transponder Timeout field
Note: This specifies an amount of time a transponder must be away from a capture zone before
it is reported again as a new transaction when it is detected.
6. Repeat steps 2 through 5 to individually configure the other Ports, or enter the number of a configured Port
in the field and click Set button to duplicate setting automatically to the remaining channels.
Allowing the Reader to calculate the optimum voting time using Dynamic Voting Control
Prerequisites: Connect a service laptop to the Lane controller port to access the web interface.
Refer to Connecting a service laptop to the Reader, page 34.
1. Go to the Channels web page.
2. Set the Dynamic Voting Control to Reader to allow the Reader to automatically set the voting time by
calculating the average capture zone span time.
Result: The following screen appears.