Operations and Maintenance Manual

_
MPR 4.1
Reader Maintenance Instructions
Confidential UM UM360479-100 Revision: Draft B4 Page 107 of 246
© Kapsch TrafficCom Canada Inc. 2022
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM360479-100 REV B4 DRAFT WIP MPR-4.1 READER OPERATIONS AND MAINTENANCE MANUAL (002).DOCX
05/25/2022 11:18
Kapsch TrafficCom
Configuring Voting Time
Manually setting a voting time gives a fixed voting time to each Port. Dynamic voting time allows the
Reader to calculate and base the voting time on the average capture zone span time (the average
time it takes for OBUs to pass through a capture zone).
Manually set the voting time for a Port
Prerequisites: Connect a service laptop to the Reader Lane Configuration port to access the web
interface. Refer to Connecting a service laptop to the Reader, page 34.
1. Go to the Channels web page.
Result: The following screen appears.
2. In the LPT/FME Voting Time field enter a voting time in milliseconds, to set the voting time for LPT and
FME OBUs.
3. In the Voting Time (all other tags) field enter a voting time in milliseconds, to set the voting time for all
OBUs that are not LPT or FME.
4. Click on the Group tab.
Result: The following screen appears.