Figure 5-12 Schematic of a three-Reader LC network
Reader connections to the LC and Inter-Reader via Ethernet
Reader IP addresses
Each ethernet port in an IR or LC network must have a unique IP address. The IP addresses should be
set as required for the site network topology. Default reader IP addresses are:
• Lane Controller Ethernet port: 192.168.1.50
• Inter Reader Ethernet port: 192.168.0.50
Setting the reader IP addresses
Prerequisites: Connect the service laptop to the Lane Controller port to access the Web interface.
Refer to Connecting a service laptop to the Reader, page 34.
Note: A secure record of the IP addresses should be maintained to aid network
troubleshooting. The Lane controller Ethernet IP addresses will be required if requesting
remote assistance from Kapsch Service.
1. Go to the General web page.
2. Assign an IP address to the parameter Reader IP Address so that the Reader is accessible on the LC
network.
3. Assign the gateway IP address to the parameter Default Gateway IP so that the Reader can communicate
via a gateway device such as a router.