Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader 2.4 Operating Instructions
Confidential UM 360467-110 Revision: B Page 93 of 247
© Kapsch TrafficCom Canada Inc. 2021
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM 360467-110 REV B3 MPR 2.4 CLEAN.DOCX 03/02/2021 1:01
Kapsch TrafficCom
Command
How to execute
Who can
execute
Prmtr.
Name
Default Value
Prmtr.
Range
Purpose of command
Invalid Tag: Visual
On the Toll Collection
Programming (TCP)
panel on the Tag
Protocol page:
With OBU feedback
enabled, and Type 2
selected, select a
feedback option from
the OBU Visual Feedback
drop-down box.
User with
Change
Configuration
permission
O2IVDV
Off
Off
Green: 2s
Red: 2s
Yellow: 2s
Specifies the visual feedback to provide in the case
of an invalid tag.
To configure how long and what color an OBU LED
flashes to indicate a successful transaction.
OBU feedback type 2 parameters only apply to TDM
tags if a status file has been transferred to the
Reader.
Lost/Stolen Tag:
Audible
On the Toll Collection
Programming (TCP)
panel on the Tag
Protocol page:
With OBU feedback
enabled, and Type 2
selected, select a
feedback option from
the OBU Audible
Feedback drop-down
box.
User with
Change
Configuration
permission
O2LSTA
Off
Off
4 cycles: 0.25s ON,
0.25s OFF
1 cycle: 1.5s ON
3 cycles: 0.5s ON,
0.2s OFF
Specifies the audible feedback to provide for a
lost/stolen tag.
To configure how long and how many times an OBU
beeps to indicate a successful transaction.
OBU feedback type 2 parameters only apply to TDM
tags if a status file has been transferred to the
Reader.