Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader 2.4 Operating Instructions
Confidential UM 360467-110 Revision: B Page 88 of 247
© Kapsch TrafficCom Canada Inc. 2021
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM 360467-110 REV B3 MPR 2.4 CLEAN.DOCX 03/02/2021 1:01
Kapsch TrafficCom
Command
How to execute
Who can
execute
Prmtr.
Name
Default Value
Prmtr.
Range
Purpose of command
Transaction number
programming
On the Toll Collection
Programming (TCP)
panel on the Tag
Protocol page:
With Transaction
number programming
enabled, select the
appropriate calculation
type from the
Transaction number
programming box.
User with
Change
Configuration
permission
TFRM__
Reprogram with
16 bit
sequential
transaction
number.
Don’t reprogram
transaction field.
Reprogram with
16 bit random
number.
Reprogram with
16 bit sequential
transaction
number.
Reprogram with 8
bit random
number and 8
bit sequential
number.
Sets the way the Reader creates an OBU transaction
number.
To choose how the Reader determines OBU
transaction numbers.
OBU Feedback
On the Toll Collection
Programming (TCP)
panel on the Tag
Protocol page:
Select the OBU Feedback
switch.
User with
Change
Configuration
permission
rw_OBU
0
0-1
Disabled: programs feedback-type OBUs to not
provide feedback.
Enabled: programs feedback-type OBUs to provide
feedback.
To configure feedback-type OBUs to notify when an
ETC transaction has occurred.
TC Date/Time
On the Toll Collection
Programming (TCP)
panel on the Tag
Protocol page:
With TCP enabled, select
TC Date/Time switch
User with
Change
Configuration
permission
TCDTTM
0
0-1
Disabled: Reader Date/Time not written to OBU TC
data fields.
Enabled: Reader Date/Time written to OBU TC data
fields.
To keep a record in OBUs of the TC transaction time.