Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader 2.4 Operating Instructions
Confidential UM 360467-110 Revision: B Page 82 of 247
© Kapsch TrafficCom Canada Inc. 2021
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM 360467-110 REV B3 MPR 2.4 CLEAN.DOCX 03/02/2021 1:01
Kapsch TrafficCom
Command
How to execute
Who can
execute
Prmtr.
Name
Default Value
Prmtr.
Range
Purpose of command
6C Agency ID
(Decimal)
On the 6C Programming
panel on the Tag
Protocol page, with
Enable switch ON.
Enter a numeric Agency
ID.
User with
Change
Configuration
permission
6C_AID
0
0 - 4095
Sets the agency ID
To keep a record in OBUs of the agency ID
6C Read Mode:
On the 6C Programming
panel on the Tag
Protocol page
Select 6C Read Mode
from the drop-down list.
User with
Change
Configuration
permission
6C_RDM
EPC only (0)
EPC only (0)
EPC+TID (1)
EPC + UM (2)
Specifies what mode to use when reading ISO
18000-6C tags.
Multi-tag reads
(Q = 2)
On the 6C Programming
panel on the Tag
Protocol page
Set toggle switch to ON
to enable.
User with
Change
Configuration
permission
6C__MT
0
0 - 1
Enable to allow multiple ISO 18000-6C tags to be
read per frame, at the expense of a longer frame
time.
When disabled, only one 6C tag may be read per
frame. When enabled, the 6C Q-value = 2; when
disabled the Q-value is 0.
6C Mask Select
On the 6C Programming
panel on the Tag
Protocol page
Select 6C mask from the
drop-down list.
User with
Change
Configuration
permission
6C_MSK
Standard (0)
Standard (0)
Puerto Rico (1)
Custom (2)
Specify what 6C Read Masking to use when reading
6C tags.