Operations and Maintenance Manual
_
JANUS
®
Multi-Protocol Reader 2.4 Operating Instructions
Confidential UM 360467-110 Revision: B Page 81 of 247
© Kapsch TrafficCom Canada Inc. 2021
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM 360467-110 REV B3 MPR 2.4 CLEAN.DOCX 03/02/2021 1:01
Kapsch TrafficCom
Command
How to execute
Who can
execute
Prmtr.
Name
Default Value
Prmtr.
Range
Purpose of command
Plaza ID
On the TDM Tag
Programming panel on
the Tag Protocol page,
with TDM Tag
Programming enabled,
enter a numeric Plaza ID.
User with
Change
Configuration
permission
PID___
0
0-127
Sets Plaza ID
To keep a record in OBUs of the Plaza ID
Agency ID
On the TDM Tag
Programming panel on
the Tag Protocol page,
with TDM Tag
Programming enabled,
enter a numeric Agency
ID.
User with
Change
Configuration
permission
AID___
0
0 - 127
Sets the agency ID
To keep a record in OBUs of the agency ID
6C Read-Only Mode
On the 6C Programming
panel on the Tag
Protocol page, check
Enable switch:
User with
Change
Configuration
permission
6CROLY
1
0-1
Controls whether the reader writes or does not
write to 6C tags.
6C Try-To-Program
Timeout [sec]
On the 6C Programming
panel on the Tag
Protocol page, with
Enable switch ON:
Enter time quantity in
seconds in the 6C Try-To-
Program Timeout [sec]
field
User with
Change
Configuration
permission
6C_TTP
500
0-4294967295
Specifies, in seconds, the duration after which
additional programming attempts will be made with
an existing 6C tag.