Operations and Maintenance Manual
_
JANUS
®
Multi-Protocol Reader 2.4 Operating Instructions
Confidential UM 360467-110 Revision: B Page 79 of 247
© Kapsch TrafficCom Canada Inc. 2021
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM 360467-110 REV B3 MPR 2.4 CLEAN.DOCX 03/02/2021 1:01
Kapsch TrafficCom
Command
How to execute
Who can
execute
Prmtr.
Name
Default Value
Prmtr.
Range
Purpose of command
Switchover on
Ethernet IRIF Link
Down
On the Switchover panel
of the General page:
With Ethernet LC
communications
enabled, select the
Switchover on Ethernet
IRIF Link Down switch.
User with
Change
Configuration
permission
SOIRIF
0
0-1
Disabled: switchover does not occur when the
Ethernet IRIF link is down.
Enabled: Enable means switch-over if a connection
to an adjacent reader over the Ethernet interface is
down.
Statistics Retention
period
On the Reader Statistics
panel of the General
page:
Enter the appropriate
quantity in the Statistics
Retention period [7–90
days] field
User with
Change
Configuration
permission
SDSRET
30
7 - 90
Use to specify how many days transaction summary
data is retained.
Statistics Summary
Interval
On the Reader Statistics
panel of the General
page:
Enter the appropriate
quantity in the Statistics
Summary Interval [1–30
minutes] field
User with
Change
Configuration
permission
SDSINT
15
1 - 30
Generates transaction summary records into
database at specified time interval. Values below 5
minutes for testing only. May be automatically
adjusted by reader based on load and retention
period
Generates transaction summary records into
database at specified time interval.