Operations and Maintenance Manual
_
JANUS
®
Multi-Protocol Reader 2.4 Operating Instructions
Confidential UM 360467-110 Revision: B Page 76 of 247
© Kapsch TrafficCom Canada Inc. 2021
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM 360467-110 REV B3 MPR 2.4 CLEAN.DOCX 03/02/2021 1:01
Kapsch TrafficCom
Command
How to execute
Who can
execute
Prmtr.
Name
Default Value
Prmtr.
Range
Purpose of command
System Identification
From the home page,
click Identify in the
Manage panel.
anyone
N/A
N/A
N/A
Causes the CTM MC LED to flash green-red-amber-
green three times
Used to confirm which reader is being accessed.
Reboot
From the home page,
click Reboot in the
Manage panel.
anyone
N/A
N/A
N/A
Reboots the Reader. If done on the Primary side of a
redundant reader the reader will switchover
automatically to the Secodnary side.
General page
Site Name
On the Site Information
panel of the General
page:
Type a Reader name in
Site Name text.
User with
Change
Configuration
permission
SITENM
no default value
String length: 32
Sets the site name shown in the web interface
banner, reported in reader log files and when saving
the reader configuration.
NOTE: The reader will automatically add a "-pri"
suffix for the Primary side CTM, and a "-sec" suffix
for the Secondary side.
Site Type
From the Site
Information panel of the
General page:
Select a Reader type in
Site Type drop down
menu.
User with
Change
Configuration
permission
SITETY
PLAZA
PLAZA
ORT (with straddle
antennas)
ORT (no straddle
antennas)
ORT stagered
Lab/table top
demo
Sets the site type used only for descriptive purposes.